Izdelki za visok tlak (5)

Regulator tlaka plina RDU100(63) - 100(63) bar, DN15-100mm, industrijski, pilotno upravljan, neposreden tok

Regulator tlaka plina RDU100(63) - 100(63) bar, DN15-100mm, industrijski, pilotno upravljan, neposreden tok

Gas pressure regulators of the RDU type are designed to reduce and automatically maintain gas pressure “after itself” using the set value. Gas pressure regulators of the RDU type are used at the facilities for main gas pipelines: Gas distribution stations, Gas purification and dehydration installations, Compressor stations, Gas fields. Distinctive features of the RDU regulators: The simplicity of the device, Tightness at complete closure of the valve, Possibility to automate the reduction process. Upper setting limit, MPa/(bar)-1.2/(12) or 4.0/(40) depending on the setting device. Lower setting limit, MPa/(bar)-0.15/(1.5) or 1.2/(12) depending on the setting device. More information on our website.
Hidravlična preša HF-P100

Hidravlična preša HF-P100

Press features: Rated force: 1000 kN; Working stroke: 300 mm; Working pressure: up to 160 bar; Running time: 6 seconds; Total power of engines: 2.2 kW; Power supply: 380 V, 50 Hz; Control: semi-automatic (sensors); Dimensions: 1100 * 1000 * 2110 mm Weight: 2,7 t.
Lito aluminij - litje pod visokim tlakom, litje pod nizkim tlakom, gravitacijsko litje, obdelava litij

Lito aluminij - litje pod visokim tlakom, litje pod nizkim tlakom, gravitacijsko litje, obdelava litij

Aluminum casting workshop: producing castings by means of die-casting, low pressure casting and gravity casting. The Workshop capacity is 1500 tons of good cast per year. Aluminium cookware casting workshop: producing cookware with non-stick casting. Machine-assembly workshop: manufacturing of machined parts and fabricated assemblies. Alloys manufacturing subdivision: recycling of aluminium wastes and dross. Manufacturing of aluminium secondary alloys.
Regulatorji plinskega tlaka s toplotnim generatorjem tipa RDU-T - 100(63) bar, DN50-150 mm, industrijski, pilotno upravljani, neposreden tok

Regulatorji plinskega tlaka s toplotnim generatorjem tipa RDU-T - 100(63) bar, DN50-150 mm, industrijski, pilotno upravljani, neposreden tok

Gas pressure regulators of the RDU-T type with a heat generator are designed for automatic regulation of gas pressure “after itself” of the set value at the facilities of high pressure gas pipelines. They are used at: Gas distribution stations. Gas purification and dehydration installations. Gas fields. Compressor stations, etc. The regulators are designed for operation at ambient temperatures from +50 C to -40 C and relative humidity up to 95% at a temperature of +35 C. Distinctive features of RDU-T regulators: The RDU-T regulators differ from the RDU regulators of the same class by the heating of the shut-off and regulating device in the zone of gas throttling using specially mounted heat generators which operate without an external energy source by taking a part of the kinetic and potential energy of the compressed main gas. The heating temperature is sufficient to prevent hydrate formation processes. More information on our website.
Regulatorji plinskega tlaka RD-M100(63) - 100(63) bar, DN15-150mm, industrijski, pilotno upravljani, neposreden tok

Regulatorji plinskega tlaka RD-M100(63) - 100(63) bar, DN15-150mm, industrijski, pilotno upravljani, neposreden tok

Gas pressure regulators RD-M are designed to reduce and automatically maintain the gas pressure “after itself” at the set value. Gas pressure regulators of the RD-M type are used at the facilities for main gas pipelines: Gas distribution stations, Gas purification and dehydration installations, Compressor stations, Gas fields. Distinctive features of the RD-M regulator: Hydrate formation in the “seat-valve” contact zone does not affect the regulator operation. Tightness at full closing of the valve. Smooth regulation characteristics due to the use of an oil compensator. High accuracy of maintaining the set pressure. High maintainability (possibility to repair wearing parts without removing the regulator body from the reduction line). Possibility to automate the reduction process. Upper setting limit, MPa/(bar)-1.2/(12) or 4.0/(40) depending on the setting device. Lower setting limit, MPa/(bar)-0.15/(1.5) or 1.2/(12) depending on the setting device. More information on our website.